87

4.3.8 Diode Test (

)

CAUTION

To avoid damage to instrument

Turn off the power to the circuit under test before starting measurement in order to prevent any
excessive voltage from being applied to the instrument.

1) Turn the function switch to the “

• ” position.

Press the SELECT key to select Diode test.

(The display shows the

symbol.)

2) Plug the test leads into the input terminals.

3) Connect the test leads to the diode and then read the value when it

stabilizes.

Test leads

Red

Black

<Forward-bias Diode Test>

Connect the black test lead to the cathode and the red test lead to the anode.
Silicon diodes should give a reading of approximately 0.5V and light-emitting diodes a reading
between approximately 1.5V and 2.0V.

<Reverse-bias Diode Test>

Connect the black test lead to the anode and the red test lead to the cathode.
Normally, the display shows the “ OL ” symbol, indicating that the diode under test is normal.
The diode is defective if the display gives a certain voltage level.

Black test

lead

Red test

lead

Figure 1 Forward-bias

Diode Test

Red test

lead

Black test

lead

Figure 2 Reverse-bias

Diode Test