<Percentage (%) calculation>

Calculates and display the percentage value according to the following equation: % value

=(measured value – reference value)/reference value

1) Take a measurement to set the reference value.

2) Press the REL /% key.

(The display shows the“ ” symbol and the sub-display shows the reference value.)

3) Take another measurement.

Press the REL /% key again. (The display shows the“ % ” symbol.)

4.3.20 Decibel calculation (dBm, dB

V

)

The instrument can perform logarithmic calculations on a AC voltage.

dBm : 20log

Measured voltage value

Reference resistance value × 10

-3

(1mW/Reference resistance (Ω)=0dBm)

Measured voltage value

dB

V

: 20log

1(V)

1) Turn the function switch to the

V or

mV position.

2) Press the SELECT key to select dBm dB

V

.

(The display shows the “ dBm ”, “ dB ” symbol.)

3) Connect the test leads to the circuit under test and then read the value when it stabilizes.

4) When calculating relative value, press the REL /% key.

Note

The instrument can switch (select) reference resistance value when measuring dBm.
The reference resistance value is switched as follows every time the RANGE key is pressed.
(Shown in sub-display.)
Reference resistance value:

4,8,16,32,50,75,93,110,125,135,150

200,250,300,500,600,800,900,1000,1200

Default value: 600Ω

The default settings can be changed. Refer to the Set-up function.