Caution – KYORITSU 1062 User Manual

Page 34

Advertising
background image

92

4.3.14 Frequency Measurement (Hz), Duty cycle ratio (Hz)

CAUTION

To avoid damage to instrument

Turn off the power to the circuit under test before starting measurement in order to prevent any
excessive voltage from being applied to the instrument.

1) Turn the function switch to the voltage(

V,

mV) or

the current (µ A, mA, A ) position.

2) Press the SELECT key to select the range of frequency. (The

display shows the unit of frequency.)

3) Plug the test leads into the input terminals.

Plug the red test lead into the suitable input terminal (“ A” or

“µA•mA”) for current value when current measurement.

4) Connect the test leads to the under test and then read the

value when it stabilizes. The display shows frequency value

in main-display and duty cycle ratio value in sub-display.

Test leads

Red

Black

Test leads

Red

Black

Test leads

Red

Black

<Voltage>

<Current>

Advertising