4 option locations in the device, 2 dimensions of the motor starter, 1 power rating / motor size – NORD Drivesystems BU0135 User Manual

Page 20: 2 dimensions of the motor starter 2.2.1

Advertising
background image

SK 105E…175E Motor Starter Manual

20

Pre-series version

BU 0135 GB-2713

2.1.4

Option locations in the device

The drawing above shows the various mounting locations for the optional modules. Option location 1 is used
for the mounting of an internal bus module or internal mains unit. External bus modules, 24 V power
supplies can be implemented at option locations 3L or 3R. Option locations 4 and 5 are used for the
installation of M12 sockets or plug connectors or for cable glands. Of course, only one option can be
mounted at a single option location.

Option
location

Position Meaning

Size

Sizes 1 - 2

Comments

1

Internal

Mounting location for customer units SK CU4-…

3*

on side

Mounting location for
· External technology units SK TU4-…
· HARTING plug connectors

3 A/B*

on side

Cable gland

M25

Not available if location
3 is occupied or
SK TU4-… is fitted.

4 *,

5 *

on side

Cable gland

M16

Not available if
SK TU4-… is fitted.

* R and L (right and left side)

2.2 Dimensions of the motor starter

2.2.1

Power rating / Motor size

Size

Mains / Power category SK 1x5E

3~ 200-240V

3~ 380-500V

Size I

0.12 ... 1.5kW

0.25 ... 3.0kW

Size II

2.2 ... 4.0kW

4.0 ... 7.5kW

Advertising