3 table of possible warning messages, N 6.3), On 6.4) – NORD Drivesystems BU0135 User Manual

Page 79: D 6.3

Advertising
background image

6 Status messages

BU 0135 GB-2713

Pre-series version

79

6.3 Table of possible warning messages

Display

Warning

Text in the Parameter Box

Cause

Remedy

Group

Details in
P700 [-02]

C002

2.0

Overtemp. Motor PTC
“Overtemperature of motor PTC“
(from thermistor)

Warning from motor temperature sensor (triggering
threshold reached)

Reduce motor load

C003

3.0

Overcurrent I²t limit

Warning: I

2

t limit,

(e.g. output current > Nominal motor current)

Continuous motor overload

6.4 Table of possible reasons for the operating status "switch-on disabled"

The following table summarises the messages which are generated if the motor starter cannot be enabled,
although no fault is present.

Display

Reason

Text in the Parameter Box

Cause

Remedy

Group

Details in
P700 [-03]

I000

0.1

Disable voltage from IO

If the function "disable voltage"is parameterised, input
(P420) is at Low

Set "input high"

Check signal cable (broken cable)

0.3

Disable voltage from bus

Only with control by USS protocol / NordCon:
Control word Bit 1 "Low"

0.5

Enable on start

Enable signal was already present during the initialisation
phase (after mains "ON" or control voltage "ON").

Only issue enable signal after completion of initialisation
(i.e. when the motor starter is ready)

Activation of "Automatic Start" (P428)

I006

6.0

Mains voltage error

Mains failure

Advertising