HP Systems Insight Manager User Manual

Page 603

Advertising
background image

Description

Data Type

Column Name

Not standard; indicates whether the power supply is present
in the chassis

NVARCHAR(32)

dc_PowerSupplyPresent

The status of the power supply (noError (1), generalFailure
(2), bistFailure 32), fanFailure (4), tempFailure (5),
interlockOpen (6), epromFailed (7), vrefFailed (8),
dacFailed (9), ramTestFailed (10), voltageChannelFailed
(11), orringdiodeFailed (12), brownOut (13),
giveupOnStartup (14), nvramInvalid (15),
calibrationTableInvalid (16))

NVARCHAR(64)

dc_PowerSupplyStatus

Not standard; the redundancy state of the power supply

NVARCHAR(32)

dc_PowerSupplyState

Not standard; capacity and or output power of the power
supply in watts

INT

dc_CurrentOutputInfo

OtherIdentifyingInfo captures additional data, beyond
DeviceID information, that could be used to identify a
LogicalDevice

NVARCHAR(256)

OtherIdentifyingInfo

Indication of the type the power supply device including:

"0" = Unknown

"1" = Other

"2" = Compute Cabinet Bulk Power Supply

"3" = Compute Cabinet System Backplane Power Supply

"4" = Compute Cabinet I/O chassis enclosure Power
Supply

"5" = Compute Cabinet AC Input Line

"6" = I/O Expansion Cabinet Bulk Power Supply

"7" = I/O Expansion Cabinet System Backplane Power
Supply

"8" = I/O Expansion Cabinet I/O chassis enclosure Power
Supply

"9" = I/O Expansion Cabinet AC Input Line

SMALLINT

Type

Position is a free-form string indicating the placement of a
PhysicalElement. It can specify slot information on a
HostingBoard, mounting site in a Cabinet, or latitude and
longitude information, for example, from a GPS. It is part
of the key of the Location object.

NVARCHAR(64)

Location

Position is a free-form string indicating the placement of a
PhysicalElement. It can specify slot information on a
HostingBoard, mounting site in a Cabinet, or latitude and
longitude information, for example, from a GPS. It is part
of the key of the Location object.

NVARCHAR(64)

PhysicalPosition

The Caption value can be one of the following, depending
on the device type:
• Compute Cabinet Bulk Power Supply
• Compute Cabinet Backplane Power Supply
• Compute Cabinet I/O Chassis Enclosure Power Supply
• Compute Cabinet AC Input Line
• I/O Expansion Cabinet Bulk Power Supply
• I/O Expansion Cabinet Backplane Power Supply
• I/O Expansion Cabinet I/O Chassis Enclosure Power

Supply

• I/O Expansion Cabinet AC Input Line
• Cooling Device Slot
• Power Device Slot
Note: This property may not be available when the cell is
powered off.

NVARCHAR(64)

Caption

Displays manufacturer Hewlett-Packard

NVARCHAR(64)

Manufacturer

Database tables 603

Advertising