Table 3-79 Values for the Trace Level Setting

Value

Description

0

No trace is output.

1

Only error information is output.

2

Program operation summaries are output.

3

Program operation details are output.

4

All information is output.

If an error occurs, you might have to set the trace level to 1 or higher to

collect any trace information.

The higher this value is set, the more information that will be output. As the

amount of trace information to be output increases, it will take less time to

overwrite the old trace information with the new information.

For normal operation, we recommend that you set the trace level to 0. If you

set the trace level to a value higher than necessary, HDLM performance

might decrease, or trace information required to analyze the cause of an

error might be overwritten.

The following is an example of using a command to set the trace level.

# /opt/DynamicLinkManager/bin/dlnkmgr set -systflv 1

Specify the trace level as a number.

Setting the Error Log File Size

The error log file size (the HDLM manager log (dlmmgrn.log (n indicates a file

number from 1 to 16))) can be set.

You can specify a value (in KB) from 100 to 2000000 for the error log file

size. The specified value is applied for HDLM manager logs.

When an error log file reaches its maximum size, the information in the oldest

error log file will be overwritten with new information. By specifying both the

log file size and the number of log files, you can collect up to 32000000KB

(approximately 30GB) of error log information.

The following is an example of using a command to set the error log file size.

# /opt/DynamicLinkManager/bin/dlnkmgr set -elfs 1000

Specify the size of the error log file in KB.

Setting the Number of Error Log Files

The number of the error log files (the HDLM manager log (dlmmgrn.log (n

indicates a file number from 1 to 16))) can be set.

Creating an HDLM Environment

3-195

Hitachi Dynamic Link Manager (for Linux®) User Guide

Advertising
This manual is related to the following products: