Message ID

Message Text

Explanation

Make sure that the disk has

enough unused capacity.

KAPL04012-E

Could not create a

communication pipe. RC =

aa...aa

Details

HDLM manager could not start

normally because it was unable to

create a pipe file, which is used in

communication with HDLM

commands.
aa...aa: OS error code(decimal

(base-10) number)

Action

Execute the DLMgetras utility for

collecting HDLM error information,

and then contact your HDLM

vendor or the maintenance

company if there is a maintenance

contract for HDLM. For details on

the DLMgetras utility, see

DLMgetras Utility for Collecting

HDLM Error Information on page

7-3

.

KAPL04013-E

Input is impossible via the

communication pipe. RC =

aa...aa

Details

Data could not be read from the

pipe file while communicating with

an HDLM command.
aa...aa: OS error code (decimal

(base-10) number)

Action

Execute the DLMgetras utility for

collecting HDLM error information,

and then contact your HDLM

vendor or the maintenance

company if there is a maintenance

contract for HDLM. For details on

the DLMgetras utility, see

DLMgetras Utility for Collecting

HDLM Error Information on page

7-3

.

KAPL04014-E

Output is impossible via the

communication pipe. RC =

aa...aa

Details

Data could not be written to the

pipe file while communicating with

an HDLM command.
aa...aa: OS error code (decimal

(base-10) number)

Action

Execute the DLMgetras utility for

collecting HDLM error information,

and then contact your HDLM

vendor or the maintenance

company if there is a maintenance

contract for HDLM. For details on

8-34

Messages

Hitachi Dynamic Link Manager (for Linux®) User Guide

Advertising