Notes on Using HDLM

Note the following when using HDLM.

Notes Common to OSs

The following notes are common to OSs:

Do not activate the same volume group concurrently from multiple

servers.

When a path error exists, the period of time required to return a response

to the application that made an I/O request to HDLM depends on the

timeout values specified for the fibre channel switch and HBA.
Therefore, if an error occurs in all the paths for a single LU, this response

time will be the total period of time required for the corresponding fibre

channel switches and HBAs to detect a timeout for the I/O requested for

each path.
For details on the timeout values for fibre channel switches and HBAs, see

the appropriate manual for the device. The following figure gives an

overview of the period required to return a response from the time an

application requests an I/O to the time the application receives the

response.