If all the following conditions are satisfied, even a path in the normal

status might become Offline(E) or Online(E):

¢

A storage system that has a SATA drive is being used.

¢

There is a heavy I/O load on the storage system.

¢

Path health checking is set to ON.

If this problem happens, reduce the I/O load, and then return the path

status to Online by performing an online operation.

Although the following messages are output when you load the alert

driver and the filter driver respectively, HDLM operations are not affected.

sddlmadrv: unsupported module, tainting kernel.

sddlmadrv: module license 'Proprietary: Contact Hitachi for any

bugs' taints kernel.

Paths for which a value equal or greater than 0000000000000100 is

displayed for the target ID (hexadecimal number) in PathName as a result

of executing the dlnkmgr command's view operation (with either the-
path or -lu parameter specified) are the paths whose status changes to
Offline(E) because the host was restarted while an error occurred with

some paths.
The status of such Offline(E) paths is not changed to online by using

the online command or the automatic failback function. To change the

status of such paths to online, execute the dlmcfgmgr utility (dlmcfgmgr
-r).

Notes When Using Red Hat Enterprise Linux AS4/ES4, or Oracle

Enterprise Linux 4

Note the following when your OS is Red Hat Enterprise Linux AS4/ES4, or

Oracle Enterprise Linux 4:

To update a kernel package or apply an OS update package, remove

HDLM first. Perform the update and then install HDLM again.
For detailed procedures, see

Updating Kernel Packages and Applying OS

Update Packages on page 4-8

.

SCSI devices corresponding to an HDLM device can be removed

dynamically even while the HDLM device is in use. Before doing so,

perform the following operations:

a

.

Unmount any devices mounted on the HDLM device.

b

.

Execute the dlmcfgmgr -o command to exclude the HDLM device

from management.

When a device is dynamically configured by using the udev function, the

messages shown below might be output to the console or syslog.

However, HDLM operations are not affected.
Output example:

scsi_id[a01]: Cannot find sysfs device associated with /sys/