Information Collected by the DLMgetras Utility for

Collecting HDLM Error Information

Immediately after an error occurs, execute the DLMgetras utility for collecting

HDLM error information, since restarting the machine might delete error

information before the information is collected by DLMgetras.

For details about the DLMgetras utility and the error information it collects,

see

DLMgetras Utility for Collecting HDLM Error Information on page 7-3

.

Checking Error Information in Messages

When you want to configure the system so that HDLM messages are output

to syslog, specify user for the name of the system function defined in the

syslogd settings file. In the following example, the system function name is
user, and messages at the Information level or higher are output to

the /etc/syslog.conf file:

user.info /tmp/syslog.user.log

You can check path errors by referring to the KAPL08xxx messages that are

output to the syslog.

To obtain detailed information about a path failure, check the execution

results of the view operation as indicated by the error message.

For details on the view operation, see

view (Displays Information) on page

6-31

.

The following is an example of a message:

KAPL08022-E Error in path occurred. A path error occurred. ErrorCode

= aa...aa, PathID = bb...bb, PathName =

cc...cc.dd...dd.ee...ee.ff...ff, DNum = gg...gg, HDevName = hh...hh

The message elements are explained below:

ErrorCode

The error number generated when Linux detects a path error.

PathID

The ID assigned to a path. This ID is called the AutoPATH_ID.

AutoPATH_IDs are re-assigned every time the host is restarted. When you

want to add a new LU without restarting the host, AutoPATH_IDs are re-

assigned to each path of the LU when you execute the dlmcfgmgr utility.
This path ID is also the same as PathID displayed by the dlnkmgr

command's view operation. For details on this view operation, see

view

(Displays Information) on page 6-31

.

PathName

5-2