background image

4.

Click Upgrade Firmware.

The selected management processors are upgraded. Although this utility enables you to
upgrade hundreds of management processors, only 25 management processors are upgraded
simultaneously. Network activity is considerable during this process.

5.

After the upgrade is complete, click Next.

During the firmware upgrade process, all buttons are deactivated to prevent navigation. You can
still close the application by clicking the X at the top right of the page. If the GUI is closed during
programming of firmware, the application continues to run in the background and completes the
firmware upgrade on all selected devices.

Selecting a directory access method

After you click Next in the Upgrade Firmware on Management Processors window, the Select the
Desired Configuration window appears (

Figure 112

). You can select which management processors

to configure (with respect to schema usage) and how to configure them. The Select the Desired
Configuration window helps to prevent an accidental overwrite of iLOs already configured for HP
schema, or iLOs that have directories turned off.

The selections you make in this window determine the windows that are displayed when you click
Next.

Figure 112 Select the Desired Configuration window

To configure the management processor for directory services, see

“Configuring directories when

HP extended schema is selected” (page 202)

. To configure the management processor for Schema-free

(default schema) directories support, see

“Configuring directories when schema-free integration is

selected” (page 206)

.

HP Directories Support for ProLiant Management Processors utility 201