1.

Click Test Settings on the Security

→Directory page.

The Directory Tests page opens, as shown in

Figure 24 (page 55)

.

Figure 24 Directory Tests page

This page displays the results of a series of simple tests designed to validate the current directory
settings. Also, it includes a test log that shows test results and any detected issues. After your
directory settings are configured correctly, you do not need to rerun these tests. The Directory
Tests page does not require that you be logged in as a directory user.

2.

In the Directory Test Controls section, enter the DN and password of a directory administrator.

Directory Administrator Distinguished Name—Searches the directory for iLO objects,
roles, and search contexts. This user must have rights to read the directory.

Directory Administrator Password—Authenticates the directory administrator.

HP recommends that you use the same credentials that you used when creating the iLO objects
in the directory. These credentials are not stored by iLO; they are used to verify the iLO object
and user search contexts.

3.

In the Directory Test Controls section, enter a test user name and password.

Test User Name—Tests login and access rights to iLO. The name does not have to be
fully distinguished because user search contexts can be applied. This user must be
associated with a role for this iLO.

Test User Password—Authenticates the test user.

Typically, this account is used to access the iLO processor being tested. It can be the directory
administrator account, but the tests cannot verify user authentication with a superuser account.
These credentials are not stored by iLO.

Configuring iLO security