Install rails in the rack, Install semi-pierced washers into rack – HP StorageWorks 1000i Virtual Library System User Manual

Page 24

Advertising
background image

Because of the high ground-leakage currents associated with multiple VLSes and servers connected to the

same power source, HP recommends the use of a power distribution unit (PDU) that is either permanently

wired to the building’s branch circuit or includes a non-detachable cord that is wired to an industrial-style

plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this

purpose. Using common power outlet strips for a VLS is not recommended.

Installing the VLS1000i node into a rack (optional)

You have the option to rack the VLS1000i. To do so involves three main tasks:

Install rails in the rack
Attach rails to the VLS1000i (appliance)
Install appliance in rack

Install rails in the rack

1.

Install the two slide rails to the sides of the rack.
a. Adjust the side rail assemblies to the approximate rack depth.
b. If the rack is a 5000 or 10000 series rack, align the semi-pierced washers into the front of the

square holes in the rack so that the embossments on each washer protrude into the hole (see

Figure 3

). This holds the washers in place and prevents the screws from shifting position.

11090

Figure 3 Install semi-pierced washers into rack

c. Insert an M5 screw through each washer, or washerless hole (SystemE) in the rack, and into the

pre-threaded hole in the sheet metal on the rails (see

Figure 4

).

24

Setting up the VLS1000i hardware