Non-operational diagnostics and recovery, Multiple drive failure, Firmware corruption – HP StorageWorks 1000i Virtual Library System User Manual

Page 77

Advertising
background image

3.

Push the power button to boot the appliance from the Diagnostic/Quick Restore CD. The

CD checks the appliance and visually displays which drive has failed (see

Using the

Diagnostic/Quick Restore CD

).

4.

Remove the Diagnostic/Quick Restore CD from the CD-ROM drive

5.

Push the power button to turn off the appliance and unplug the node AC power cord.

6.

Replace the failed drive (see

Hard disk drives

).

7.

Plug in the node AC power cord and push the power button to start the appliance.
The disk array will automatically rebuild without data loss. A warning icon displays in the Hardware

Status page until the rebuild is complete. Performance will be reduces during the rebuild.

Non-operational diagnostics and recovery

In some cases, a failure will render the VLS1000i non-operational. These failures include:

Multiple

drive failure

Firmware corruption
Fatal

hardware

failure

Appliance replacement

Multiple drive failure

If multiple drives failed, it is because the RAID has failed. All data (including firmware, the configuration,

data on the virtual tape) is lost. To repair the device and return it to operational status:

1.

Insert the Diagnostic/Quick Restore CD in the CD-ROM drive.

2.

Power off the appliance (see

Powering down the VLS

) but select Restart. Do not unplug the

node AC power cord.

3.

The appliance boots from the Diagnostic/Quick Restore CD. The CD checks the appliance and

visually displays which drives have failed (see

Using the Diagnostic/Quick Restore CD

).

4.

Push the power button to turn off the appliance and unplug the node AC power cord.

5.

Replace all of the failed drives (see

Hard disk drives

).

6.

Plug in the node AC power cord.

7.

With the Diagnostic/Quick Restore CD still in the CD-ROM drive, push the power button to

start the appliance.

8.

Follow the prompts to allow the disk array to automatically rebuild the RAID and reinstall the

firmware.

9.

Remove the Diagnostic/Quick Restore CD from the CD-ROM drive.

10.

Push the power button to reboot the appliance.

11.

Configure the network address (see

Configuring the VLS appliance with the VLS Discovery tool

or

Configuring the VLS appliance via the default IP Address

for instructions).

12.

Restore from the most recently-saved configuration file to rebuild virtual devices.

Firmware corruption

If the firmware gets corrupted:

1.

Insert the Diagnostic/Quick Restore CD in the CD-ROM drive.

2.

Power off the appliance (see

Powering down the VLS

) but select Restart. Do not unplug the

node AC power cord.

3.

The appliance boots from the Diagnostic/Quick Restore CD. Follow the prompts to reinstall the

VLS firmware (see

Using the Diagnostic/Quick Restore CD

).

HP StorageWorks 1000i Virtual Library System

77

Advertising