Allied Telesis AT-S81 User Manual

Page 50

Advertising
background image

Chapter 3: Basic Switch Parameters

50

Section I: Using the Menus Interface

3. Type I to select Set Target IP Address.

The following prompt is displayed:

Enter new target IP address>

4. Type the IP address of the node you want the switch to ping and press

Enter.

5. Type N to select Set Number of Requests.

The following prompt is displayed:

Enter new number of requests>

6. Enter the number of ping requests you want the switch to perform. The

range is 1 to 10. The default is 10.

7. Type T to select Set Timeout Value.

The following prompt is displayed:

Enter new timeout value>

8. Enter the length of time in seconds the switch is to wait for a response

before assuming that a ping has failed. The range is 1 to 5 seconds.
The default is 3 seconds.

9. Type E to select Execute Ping.

The following prompt is displayed:

Execute ping or Clean ping data (E/C)>

10. Type E to execute the ping or C to clear previous ping data before

performing this ping.

Advertising