Festo Линейные модули HMP User Manual

Page 33

Advertising
background image

HMP−...−B−...

Festo HMP−...−B−... 0408NH English

33

S

Once a medium has been selected, keep this unchanged over the complete
service life of the product.

Example:
ć selected: non−lubricated compressed

air

ć continue to use: non−lubricated comĆ

pressed air.

Conversion from lubricated to non−lubriĆ
cated compressed air:
Note that the product wears.
The product will wear considerably as the
service life lubrication will be washed out.
Changing to operation with lubricated
compressed air will damage the service
life lubrication.

S

Pressurize your complete system slowly
until the operating pressure is reached.

All movements of the actuators will then
be controlled.
For slow start−up pressurization use
start−up valve type HEL−... or HEM−...Ă.

You will then avoid uncontrolled moveĆ
ments.

S

Use the product in its original state without undertaking any modifications.

S

Take into account the warnings and instructions on the product and in the
relevant operating instructions.

S

Observe also the standards specified in the relevant chapters, as well as
national and local laws and technical regulations.

Fig. 4

Fig. 5

Advertising