Fitting electric components

Warning
S Use only power units which guarantee reliable isolation of the operating

voltages as per IEC 742/EN 60742/VDE 0551 with at least 4 kV isolation
resistance (Protected Extra−Low Voltage, PELV).

Switch power packs are permited providing they guarantee reliable isolation
as per EN 60950/VDE 0805.

Please note
Strong magnetic fields in the immediate vicinity of the linear module (e.g. with
welding systems) will cause permanet magnetization of the ferromagnetic
parts. As a consequence, the switching points of the proximity switches will be
permanently shifted.

S Make sure that the product is screened against strong electromagnetic

interference (e.g. with a transformer plate).

Please note
S Use only proximity switches with the same switch output (e.g. only positive−

switching proximity switches ć PNP).

S Avoid using positive and negative−switching proximity switches together.

Preliminary fitting of the proximity switches:

1. Remove the housing cover

2 (unscrew

the quick−acting locking screws by a
quarter of a turn).

2. Remove the screws from the end cover

9

(only HMP−...−EL).

3. Pull the end cover down from the metal

suport (only HMP−...−EL).

Fig. 16