8 care and maintenance, 8care and maintenance – Festo Линейные модули HMP User Manual

Page 46

Advertising
background image

HMP−...−B−...

Festo HMP−...−B−... 0408NH English

46

8

Care and maintenance

Cleaning

S

If necessary, clean the exterior of the linear module type HMP−...−B with a soft
cloth.

The following cleaning agents are permitted:

ć soap suds (max. 60 °C)
ć petroleum ether
ć all non−abrasive cleaning agents.

S

Grease the following parts of linear module type HMP−... in accordance with
the table:

The ungreased surfaces of
the guide tube

The roller bearing of the
guide tube

Component

Lubricating
interval

If required

After every 5000 km run
(at the latest every 3 years)

Lubricating point

Guide tube

Lubricating nipple

aD

*)

Lubricating
sequence

Move the guide tube backwards and forwards by hand during the
lubricating process (the cavities will then be filled with oil to an
equal extent).

Lubricating
grease

LUB−KB2 (Klüberplex−BE31−222)

LUB−KC1 (Centoplex−2−EP)

*) For needle−pin nozzle as per DIN 1283

Fig. 36

Advertising