S

Check the shock absorbers after every 2 million strokes for:

ć oil leakage
ć hard knocking
ć the shock absorber head remains in the retracted end position / moves out

very slowly.

ć loud noises.

S

Replace the shock absorber if one of the above−mentioned signs of wear is
apparent, at the latest after every 10 million strokes (dismantling see chapter
Dismantling and repairs).

S

Check whether lubrication/testing must be carried out more frequently.

This may be necessary if:

ć the temperature loading is high
ć there is excessive dirt
ć there are fat−solvent fluids or fumes in the vicinity.

9

Dismantling and repairs

S

Switch off the power supplies:

ć Operating voltage
ć Compressed air

Replacing the shock absorbers:

1. Exhaust the system and the HMP−...Ă.

2. Remove the housing cover.

3. Unscrew the locking nut of the shock

absorber.

4. Mark the position of the adjusting sleeve.

5. Loosen the locking screws

aE.