Connecting the end module HMP−...−EL:

1. Connect the proximity switch to the

terminal strip

6 (check polarity of

proximity switch).

2. Pull the plug away for the common cable

away from the plug socket.

3. Remove approx. 6 mm of the insulation

from the cores of the common cable.

4. Connect the plug to the common cable. Fit

the plug so that the sensor cores are not
squashed.

5. Push the plug onto the connector socket

again.

6. Fasten the common cable to the metal support with the aid of the cable binder

(strain relief ).

7. Fasten the end cover

9 with the screws provided.

Fit the protective cable tube on the end cover
type HMP−...−AD/−E L as follows:

1. Select the cable exit opening above or

below.

2. Remove the locking cap.

The plug−in module plate remains in
position.

3. Fasten the screw connector with a lock nut (see Accessories).

4. Pass the pneumatic tubing and the common electric cable through the screw

connector and the protective cable tube (see Accessories).

5. Push the protective cable tube into the connector socket.

In each case the protective cable tube may only be bent or stretched within the
permitted limits (see chapter Technical data).