Festo Линейные модули HMP User Manual

Page 42

Advertising
background image

HMP−...−B−...

Festo HMP−...−B−... 0408NH English

42

Please note
S Make sure that the following points are observed (state when supplied from

factory):

Ĉ The shock absorbers must be screwed in completely and locked.
Ĉ The adjustmet sleeves must be clamped.
Ĉ The stop retainers must be screwed tight.
Ĉ The stops must be screwed in completely and locked.

S

Remove the protective caps (A) from the
restrictors (keep in a safe place).

S

Close both one−way flow control valves

ć at first completely (as supplied from

the factory),

ć then open them up again one turn.

S

Start a test run as follows:

1. Push the guide tube of the linear module

type HMP−...−B into the retracted end
position.
In the case of the HMP−...−

KP−..., press the

manual override of the clamping unit

aH.

2. Pressurize the compressed air ports:

ć at first in the retracted end position E on linear module type HMP−...−B
ć then on the the clamping unit (only with HMP−...−

KP−...).

The work load moves against the force of the shock absorber completely into
the retracted end posititon.

3. Check in a test run at a low pulse rate to ascertain whether the following

settings need to be adjusted:

ć the accurate adjudtment of the end positions
ć the desired switching points of the proximity switches
ć the signal display of the LEDs (only with HMP−...−EL)
ć the retracting and extending times.
The work load should reach the end position without striking hard against it.

4. Conclude the test run.

Fig. 30

(A)

Advertising
This manual is related to the following products: