11 eliminating faults – Festo Линейные модули HMP User Manual

Page 50

Advertising
background image

HMP−...−B−...

Festo HMP−...−B−... 0408NH English

50

11

Eliminating faults

Fault

Possible cause

Remedy

Uneven
movement of
the guide tube

One−way flow control valve
inserted incorrectly

Restrict exhaust if possible
(as supplied from the factory)

the guide tube

No compressed air supply
due to non−permitted cable
bends

Observe the min. permitted bending
radius of the protective cable tube
(see chapter Technical data)

Guide tube
does not reach
the stroke end
position

Adjusting screw of the
one−way flow control valves
closed completely

Open adjusting screw

Faults in posiĆ
tion scanning

Ferritic parts in the vicinity of
the proximity switch

Use parts made of non−magnetic
materials

LED on the
HMP−...−EL
does not

Connection fault

Cabling see chapter Fitting electric
components

does not
lightĂup

Non−permitted cable bends

Observe permitted cable bending
radius

Jumper setting on the
HMP−...−EL does not
correspond to switch output
of proximity switch

Place the jumper on the HMP−...−EL in
accordance with chapter Fitting
electric components

Mixed operation with positive
and negative−switching
proximity switches

Use proximity switches with the
same switch output

Proximity
switch does
not switch

Connection fault

Connect proximity switch in
accordance with these operating
instructions

Cable fracture

Replace proximity switch

Proximity switch defective

Heavy leakage

Linear module fitted distorted

Fasten linear module to flat surface

Seals worn

Replace worn parts
Ĉ yourself with the wearing parts kit
Ĉ Return product to Festo for repairs

Advertising
This manual is related to the following products: