51

Fault

Remedy

Possible cause

Linear module
does not
achieve the

Missing air volume

Enlarge connection cross−section
Switch volume upstream

achieve the
desired speed

Heavy friction or counterforce

Select larger linear module

Fig. 45

12

Technical data

Type

HMP−...

16−...−B

20−...−B

25−...−B

32−...−B

Design

Double−acting pneumatic cylinder

Mounting position

As desired

Medium

Filtered, lubricated or non−lubricated compressed air
(filter fineness min. 40 Ģm)
Ĉ at speeds up to max. 1 m/s (lubricated compressed

air permitted)

Ĉ at speeds over 1 m/s (always use lubricated comĆ

pressed air)

Operating pressure range

4 ... max. 8 bar

Connector thread

M5

G1/8

G1/8

G1/4

Permitted temperature range

0 °C ... max. 60 °C

Theoretical stroke force at
6Ăbar
Ĉ running forwards
Ĉ running backwards

121 N
104 N

188 N
158 N

295 N
247 N

483 N
415 N

Leakage

2 Nl/h (when new, measured at 6 bar)

Repetition accuracy

*)

<

0.01 mm

End position cushioning

Hydraulic cushioning

Cushioning length

14 mm

20 mm

20 mm

26 mm

Advertising