SECTION 5 - HYDRAULICS

3121253

– JLG Lift –

5-17

PLATFORM LEVEL UP – 3000 PSI (207 BAR)

1. Refer to the Main Pressure Relief Valve procedure

and temporarily set Main Pressure Relief Valve to
3300 psi (227.5 Bar).

2. Disconnect, cap, & plug the platform level up hose &

adapter either at the platform level master cylinder
or at port 15 of the Boom Function Valve.

USE CAUTION WHEN DISCONNECTING / RECONNECTING HOSES
ON THE PLATFORM LEVEL CIRCUIT AS THIS CIRCUIT MAINTAINS
PRESSURE.

3. Install a pressure gauge in one of the following loca-

tions:

• at port M15 of Boom Function Valve

• at port 15 of Boom Function Valve

PLATFORM
LEVEL UP
RELIEF VALVE

PLATFORM LEVEL
UP HOSE