Table 6-3. Personality Ranges/Defaults
Adjustment
Adjustment
Range
Default
Value
DRIVE
ACCEL
0.5 to 5 sec
1.5s
DECEL
0.1 to 2 sec
0.5s
MIN
0 to 25%
3%
MAX
0 to 100%
95%
ELEVATED MAX
0 to 25%
20%
CREEP MAX
0 to 45%
30%
POSITRAC
0 to 60 sec
10s
POSITRAC
50 to 250 amps
170A
LIFT
LOWER LIFT
ACCEL
0.5 to 5 sec
1.0s
DECEL
0.1 to 3.0 sec
0.5s
MIN UP
0 to 50%
18%
MAX UP
0 to 100%
83%
MIN DOWN
0 to 50%
36%
MAX DOWN
0 to 100%
58%
LIFT
UPPER LIFT
ACCEL
0.5 to 5 sec
1.0s
DECEL
0.1 to 3 sec
0.3s
MIN UP
0 to 50%
18%
MAX UP
0 to 100%
80%
CREEP UP
0 to 50%
30%
MIN DOWN
0 to 50%
20%
MAX DOWN
0 to 100%
63%
CREEP DOWN
0 to 80%
55%
SWING
ACCEL
0.5 to 5 sec
2.0s
DECEL
0.1 to 3 sec
1.5s
MIN LEFT
0 to 50%
5%
MAX LEFT
0 to 100%
30%
CREEP LEFT
0 to 100%
20%
MIN RIGHT
0 to 50%
5%
MAX RIGHT
0 to 100%
30%
CREEP RIGHT
0 to 100%
20%
TELE
ACCEL
0.5 to 5 sec
1.0s
DECEL
0.1 to 3 sec
0.5s
MIN IN
0 to 50%
22%
MAX IN
0 to 100%
45%