JLG E300 Service Manual User Manual

Page 189

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121253

– JLG Lift –

6-21

MIN OUT

0 to 50%

16%

MAX OUT

0 to 100%

35%

PLATFORM LEVEL
ACCEL

0.5 to 5 sec

1.0s

DECEL

0.1 to 3 sec

1.0s

MIN UP

0 to 50%

15%

MAX UP

0 to 80%

30%

MIN DOWN

0 to 50%

10%

MAX DOWN

0 to 80%

22%

PLATFORM ROTATE
ACCEL

0.1 to 5 sec

0.5s

DECEL

0.1 to 3 sec

0.5s

MIN LEFT

0 to 50%

13%

MAX LEFT

0 to 100%

22%

MIN RIGHT

0 to 50%

13%

MAX RIGHT

0 to 100%

22%

JIB
ACCEL

0.5 to 5.0 sec

1.0s

DECEL

0.1 to 3 sec

0.5s

MIN UP

0 to 50%

13%

MAX UP

0 to 100%

40%

MIN DOWN

0 to 50%

10%

MAX DOWN

0 to 100%

26%

MIN LEFT

0 to 50%

13%

MAX LEFT

0 to 100%

23%

MIN RIGHT

0 to 50%

13%

MAX RIGHT

0 to 100%

23%

STEER
MIN SPEED

0 to 100%

75%

MAX SPEED

0 to 100%

100%

GROUND MODE
L.LIFT UP

0 to 100%

75%

L.LIFT DOWN

0 to 100%

55%

UPPER LIFT

0 to 100%

65%

SWING

0 to 100%

30%

TELE

0 to 100%

35%

PLT.LEVEL

0 to 100%

22%

PLT.ROTATE

0 to 100%

20%

JIB (U/D)

0 to 100%

30%

JIB (L/R)

0 to 100%

23%

NOTE: Personality settings can be adjusted anywhere within the adjust-

ment range in order to achieve optimum machine performance.

1001115579-2

Table 6-3. Personality Ranges/Defaults

Adjustment

Adjustment

Range

Default

Value