JLG E300 Service Manual User Manual
Page 189
SECTION 6 - JLG CONTROL SYSTEM
3121253
– JLG Lift –
6-21
MIN OUT
0 to 50%
16%
MAX OUT
0 to 100%
35%
PLATFORM LEVEL
ACCEL
0.5 to 5 sec
1.0s
DECEL
0.1 to 3 sec
1.0s
MIN UP
0 to 50%
15%
MAX UP
0 to 80%
30%
MIN DOWN
0 to 50%
10%
MAX DOWN
0 to 80%
22%
PLATFORM ROTATE
ACCEL
0.1 to 5 sec
0.5s
DECEL
0.1 to 3 sec
0.5s
MIN LEFT
0 to 50%
13%
MAX LEFT
0 to 100%
22%
MIN RIGHT
0 to 50%
13%
MAX RIGHT
0 to 100%
22%
JIB
ACCEL
0.5 to 5.0 sec
1.0s
DECEL
0.1 to 3 sec
0.5s
MIN UP
0 to 50%
13%
MAX UP
0 to 100%
40%
MIN DOWN
0 to 50%
10%
MAX DOWN
0 to 100%
26%
MIN LEFT
0 to 50%
13%
MAX LEFT
0 to 100%
23%
MIN RIGHT
0 to 50%
13%
MAX RIGHT
0 to 100%
23%
STEER
MIN SPEED
0 to 100%
75%
MAX SPEED
0 to 100%
100%
GROUND MODE
L.LIFT UP
0 to 100%
75%
L.LIFT DOWN
0 to 100%
55%
UPPER LIFT
0 to 100%
65%
SWING
0 to 100%
30%
TELE
0 to 100%
35%
PLT.LEVEL
0 to 100%
22%
PLT.ROTATE
0 to 100%
20%
JIB (U/D)
0 to 100%
30%
JIB (L/R)
0 to 100%
23%
NOTE: Personality settings can be adjusted anywhere within the adjust-
ment range in order to achieve optimum machine performance.
1001115579-2
Table 6-3. Personality Ranges/Defaults
Adjustment
Adjustment
Range
Default
Value