JLG E300 Service Manual User Manual

Page 191

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121253

– JLG Lift –

6-23

2252

22

FUNCTION PROBLEM - TELESCOPE OUT PERMANENTLY
SELECTED

Input was CLOSED during startup

2253

22

FUNCTION PROBLEM - SWING LEFT PERMANENTLY SELECTED Input was CLOSED during startup

2254

22

FUNCTION PROBLEM - SWING RIGHT PERMANENTLY
SELECTED

Input was CLOSED during startup

2255

22

FUNCTION PROBLEM - MAIN LIFT UP PERMANENTLY
SELECTED

Input was CLOSED during startup

2256

22

FUNCTION PROBLEM - MAIN LIFT DOWN PERMANENTLY
SELECTED

Input was CLOSED during startup

2257

22

FUNCTION PROBLEM - TOWER LIFT UP PERMANENTL Y
SELECTED

Input was CLOSED during startup

2258

22

FUNCTION PROBLEM - TOWER LIFT DOWN PERMANENTLY
SELECTED

Input was CLOSED during startup

2259

22

FUNCTION PROBLEM - DRIVE FORWARD PERMANENTLY
SELECTED

Input was CLOSED during startup

2260

22

FUNCTION PROBLEM - DRIVE REVERSE PERMANENTL Y
SELECTED

Input was CLOSED during startup

2261

22

FUNCTION PROBLEM - MULTIPLE SWITCHES PERMANENTL Y
SELECTED

Input was CLOSED during startup

2262

22

FUNCTION PROBLEM - PLATFORM LEVEL UP PERMANENTLY
SELECTED

Input was CLOSED during startup

2263

22

FUNCTION PROBLEM - PLATFORM LEVEL DOWN PERMA-
NENTL Y SELECTED

Input was CLOSED during startup

2264

22

FUNCTION PROBLEM - DOS DOWN PERMANENTL Y SELECTED Input was CLOSED during startup

2265

22

FUNCTION PROBLEM - POSI DOWN PERMANENTL Y SELECTED Input was CLOSED during startup

2266

22

LIFT/SWING JOYSTICK FAULTY

Joystick was out of the Neutral position during startup

2267

22

DRIVE/STEER JOYSTICK FAULTY

Joystick was out of the Neutral position during startup

2268

22

JOYSTICKS FAULTY

Both Joysticks are faulty, or one joystick is faulting the 5 volt sup-
ply to both joysticks.

2376

23

SWING SWITCH FAULTY

Both states actively HIGH in Ground Mode

2387

23

JIB LIFT SWITCH FAULTY

Both states actively HIGH

2388

23

JIB SWING SWITCH FAULTY

Both states actively HIGH

2389

23

PLATFORM ROTATE SWITCH FAULTY

Both states actively HIGH

2390

23

TELESCOPE SWITCH FAULTY

Both states actively HIGH

2391

23

MAIN LIFT SWITCH FAULTY

Both states actively HIGH

2392

23

TOWER LIFT SWITCH FAULTY

Both states actively HIGH

2393

23

PLATFORM LEVEL SWITCH FAULTY

Both states actively HIGH

2394

23

PUMP POT FAULTY

Creep pot is OPEN circuit

2395

23

FUNCTION SWITCHES FAULTY

Function switch has both direction selected at the same time

253

25

DRIVE PREVENTED - CHARGER CONNECTED

Driving is not possible while the vehicle is charging

254

25

DRIVE & LIFT UP PREVENTED - CHARGER CONNECTED

Drive or Lift is not possible while the vehicle is charging AND is
configured to prevent all motion.

2510

25

DRIVE PREVENTED - BRAKES NOT RELEASING

No Brake pressure was detected when running the pump motor
and energizing the brake valve

Table 6-4. E300 Diagnostic Fault Codes

DTC

Flash

Code

Fault Message

Description

Advertising