BATTERY CHARGING

NOTE: Be sure that machine is parked in a well ventilated area

before charging begins.

ONLY PLUG THE CHARGER INTO A PROPERLY INSTALLED AND GROUNDED
OUTLET. DO NOT USE GROUND ADAPTORS OR MODIFY PLUG. DO NOT TOUCH
NON-INSULATED PORTION OF OUTPUT CONNECTOR OR NON-INSULATED
BATTERY TERMINAL.
DO NOT OPERATE CHARGER IF THE AC SUPPLY CORD IS DAMAGED OR IF THE
CHARGER HAS RECEIVED A SHARP BLOW, BEEN DROPPED, OR OTHERWISE
DAMAGED IN ANY WAY.
ALWAYS DISCONNECT THE CHARGER AC SUPPLY BEFORE MAKING OR BREAK-
ING THE (POS/NEG) CONNECTIONS TO THE BATTERY.
DO NOT OPEN OR DISASSEMBLE CHARGER.

1. The battery charger AC input plug is located in an

opening on the panel at the lower rear of the machine.

2. Connect the charger AC input plug to a grounded out-

let using a 3 wire heavy duty extension cord. (See
Table 5-6, “Electrical System Specifications,” on page 5-
5, f
or battery charger AC input specifications.)

3. When powered up the charger will go through a short

LED indicator self-test. The battery charger LED indica-
tors on the charger (Figure 3-2.), will flash in sequence
for two seconds. These LED indicators can be viewed

through the opening on the rear panel where the
charger AC cord is accessed.

4. The batteries are fully charged when the green light

on the battery charger status panel is illuminated.

NOTE: If the charger is left plugged in, the charger will automati-

cally restart a complete charge cycle if the batteries volt-
age drops below a minimum voltage or 30 days has
elapsed.

Figure 3-2. Charger Decal LED Indicators

GREEN (ON) -
Battery Fully Charged

AMBER (ON) -
Battery Charging

AMBER (FLASHING) -
Battery/System
Problem

RED (FLASHING) -
Charger Problem

GREEN

AMBER

RED

LEDS