9 diagnostic trouble codes (dtc), 10 dtc check table index, Diagnostic trouble codes (dtc) -14 – JLG R6 User Manual

Page 74: 10 dtc check table index -14, In section 5.9

Advertising
background image

SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

5-14

– JLG Lift –

3121684

5.9

DIAGNOSTIC TROUBLE CODES (DTC)

The DTC tables following are sorted in groups by the first two
digits, these digits represent the number of flashes the system
distress indicator lamp will flash on the platform indicator panel
when a fault occurs.

For example: a “2-1 Power-Up” on page 16 would be indicated
by 2 flashes, a pause, then 1 flash, a pause, then would keep
repeating until the fault is cleared.

The more detailed three digit code numbers in the DTC column
of the following tables are only indicated on a JLG handheld
diagnostic analyzer.

To troubleshoot multiple DTCs, start with the DTC with the
higher first two digits. If a correction is made during a check,
conclude the check by cycling the machine power off then
back on, using the emergency stop switch.

NOTICE

SHOULD A FAULT OCCUR WHICH CANNOT BE CORRECTED BY THE OPERATOR,
THE PROBLEM MUST BE REFERRED TO A MECHANIC QUALIFIED TO REPAIR
THIS MODEL OF JLG LIFT.

5.10 DTC CHECK TABLE INDEX

DTC TABLE

PAGE

0-0 Help Comments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15

2-1 Power-Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-16

2-2 Platform Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17

2-3 Ground Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18

2-5 Function Prevented. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-18

3-1 Line Contactor Open Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-20

3-2 Line Contactor Short Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21

3-3 Ground Output Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21

4-2 Thermal Limit (SOA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23

4-4 Battery Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23

6-6 Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24

7-7 Electric Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-24

8-2 LSS - Load Sensing System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-26

8-4 Elevation Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27

9-9 Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27

Advertising