6 communication, 7 electric motor, 6 communication -24 7-7 electric motor -25 – JLG R6 User Manual

Page 84

Advertising
background image

SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

5-24

– JLG Lift –

3121684

6-6 Communication

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

661

CANBUS FAILURE - POWER MODULE

The control system failed to receive messages
from the power module.

Refer problem to a qualified JLG mechanic.

6643 CANBUS FAILURE - LSS ANGLE SENSOR The control system failed to receive messages

from the angle sensor.

Refer problem to a qualified JLG mechanic.

6649 CANBUS FAILURE – TILT/TEMP SENSOR The control system failed to receive messages

from the tilt sensor.

Tilt Sensor CAN communication not received for 1000ms AND [Machine

Setup’s market configuration is AUSTRALIA OR Low Temperature Cutout is
configured].

Vehicle assumed to be elevated and tilted.
Tilt Sensor considered to be unhealthy if Australian Market. Temp Sensor con-

sidered to be unhealthy if Low Temperature Cutout configured.

Health Indicator On

Refer problem to a qualified JLG mechanic.

7-7 Electric Motor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

772

STALLED TRACTION MOTOR OR POWER
WIRING ERROR

The power module detected a problem in the
drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.

773

CAPACITOR BANK FAULT - CHECK
POWER CIRCUITS

The power module detected a problem in the
pump or drive motors' power circuit wiring.

Refer problem to a qualified JLG mechanic.