6 battery maintenance, Battery maintenance and safety practices, Battery quick-disconnect – JLG R6 User Manual

Page 69: Battery maintenance -9, Battery fluid level -9

Advertising
background image

SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

3121684

– JLG Lift –

5-9

5.6

BATTERY MAINTENANCE

Battery Maintenance and Safety Practices

NOTE: These instructions are for unsealed (wet) batteries only.

if machine is equipped with sealed batteries, no mainte-
nance other than cleaning corroded battery terminals is
required.

ENSURE THAT BATTERY ACID DOES NOT COME INTO CONTACT WITH SKIN OR
CLOTHING. WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING
WITH BATTERIES. NEUTRALIZE ANY BATTERY ACID SPILLS WITH BAKING
SODA AND WATER.
BATTERY ACID RELEASES AN EXPLOSIVE GAS WHILE CHARGING, ALLOW NO
OPEN FLAMES, SPARKS OR LIGHTED TOBACCO PRODUCTS IN THE AREA
WHILE CHARGING BATTERIES. CHARGE BATTERIES ONLY IN A WELL VENTI-
LATED AREA.
ADD ONLY DISTILLED WATER TO BATTERIES. WHEN ADDING DISTILLED
WATER TO THE BATTERIES, A NON-METALLIC CONTAINER AND/OR FUNNEL
MUST BE USED.

Check the electrolyte level of the batteries often, adding only
distilled water when required. When fully charged, battery fluid
level should be 1/8" below vent tubes. (See Figure 5-2.).

DO NOT fill to bottom of vent tubes.

DO NOT allow fluid level to go below the top of the plates

Battery Quick-Disconnect

Machines equipped with the battery
quick-disconnect allow all machine
power to be easily disconnected at the
batteries without removing battery
cables from the battery posts. To discon-
nect power, locate the RED quick-disconnect connector on top
of the batteries inside the battery compartment and pull halves
apart.

Figure 5-2. Battery Fluid Level.

1/8 "

BATTERY

FILLER CAP

FLUID LEVEL OF FULLY

CHARGED BATTERY

VENT TUBE

PLATES

1706740A