SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

3121684

– JLG Lift –

5-23

4-2 Thermal Limit (SOA)

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

421

POWER MODULE TOO HOT - PLEASE
WAIT

The power module has reached thermal cut-
out.

Power down and allow to cool.
Do not operate in ambients over 140° F (60° C).

Refer problem to a qualified JLG mechanic.

422

DRIVING AT CUTBACK - POWER MOD-
ULE CURRENT LIMIT

The drive portion of the power module has
reached thermal limit.

Refer problem to a qualified JLG mechanic.

423

LIFT UP AT CUTBACK - POWER MODULE
CURRENT LIMIT

The lift up portion of the power module has
reached thermal limit.

Refer problem to a qualified JLG mechanic.

4-4 Battery Supply

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

441

BATTERY VOLTAGE TOO LOW - SYSTEM
SHUTDOWN

A problem has been detected with the batter-
ies or power module.

Recharge batteries or check for damaged batteries.
Check battery charger function.

Refer problem to a qualified JLG mechanic.

442

BATTERY VOLTAGE TOO HIGH - SYSTEM
SHUTDOWN

A problem has been detected with the batter-
ies or power module.

May be due to improper battery charging or incorrect voltage batteries being

used.

Refer problem to a qualified JLG mechanic.

446

4421
4422

LOGIC SUPPLY VOLTAGE OUT OF RANGE The System Module logic supply voltage was

measured to be out of normal operating range.

Check for severely discharged battery, loose cables or for damaged battery;

otherwise;

Refer problem to a qualified JLG mechanic.