SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

3121684

– JLG Lift –

5-23

4-2 Thermal Limit (SOA)

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

421

POWER MODULE TOO HOT - PLEASE
WAIT

The power module has reached thermal cut-
out.

• Power down and allow to cool.
• Do not operate in ambients over 140° F (60° C).

Refer problem to a qualified JLG mechanic.

422

DRIVING AT CUTBACK - POWER MOD-
ULE CURRENT LIMIT

The drive portion of the power module has
reached thermal limit.

Refer problem to a qualified JLG mechanic.

423

LIFT UP AT CUTBACK - POWER MODULE
CURRENT LIMIT

The lift up portion of the power module has
reached thermal limit.

Refer problem to a qualified JLG mechanic.

4-4 Battery Supply

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

441

BATTERY VOLTAGE TOO LOW - SYSTEM
SHUTDOWN

A problem has been detected with the batter-
ies or power module.

• Recharge batteries or check for damaged batteries.
• Check battery charger function.

Refer problem to a qualified JLG mechanic.

442

BATTERY VOLTAGE TOO HIGH - SYSTEM
SHUTDOWN

A problem has been detected with the batter-
ies or power module.

• May be due to improper battery charging or incorrect voltage batteries being

used.

Refer problem to a qualified JLG mechanic.

446

4421
4422

LOGIC SUPPLY VOLTAGE OUT OF RANGE The System Module logic supply voltage was

measured to be out of normal operating range.

• Check for severely discharged battery, loose cables or for damaged battery;

otherwise;

• Refer problem to a qualified JLG mechanic.