1 line contactor open circuit, 1 line contactor open circuit -21, 5 function prevented – JLG R6 User Manual

Page 80

Advertising
background image

SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

5-20

– JLG Lift –

3121684

2568 TEMPERATURE CUTOUT ACTIVE –

AMBIENT TEMPERATURE TOO LOW

Reported if the ambient temperature reading
by the machine’s temperature sensor is less
than -30°C (-22 °F) the minimum allowed
temperature as set by the LOW TEMP C/O per-
sonalities setting AND TEMPERATURE CUTOUT
= YES.

If elevated, drive and steer shall be restricted to “creep”, lift down shall be

allowed at normal speed and lift up shall not be allowed. The platform alarm
shall continue to sound and the system distress indicator shall flash the
appropriate DTC.
If stowed, drive, steer, and lift down shall be allowed at normal speed how-
ever lift up functionality shall be restricted, the platform alarm shall continue
to sound and the system distress indicator shall flash the appropriate DTC.

The ambient temperature must rise to greater than TEMP OFFSET from the

LOW TEMP C/O point before interlocks and alarms are reset.

Refer problem to a qualified JLG mechanic.

2-5 Function Prevented

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

3-1 Line Contactor Open Circuit

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

311

OPEN CIRCUIT LINE CONTACTOR

There is a problem with the line contactor.

Refer problem to a qualified JLG mechanic.

314

AUXILIARY RELAY - OPEN CIRCUIT

The auxiliary relay did not close when ener-
gized.

• Check the auxiliary relay coil and the associated wiring.

Refer problem to a qualified JLG mechanic.