2-2 Platform Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

221

FUNCTION PROBLEM - HORN PERMA-
NENTLY SELECTED

The horn switch was closed during power-up
in platform mode.

Check if the horn switch is damaged, obstructed or jammed.

Refer problem to a qualified JLG mechanic.

223

FUNCTION PROBLEM - DRIVE & LIFT
ACTIVE TOGETHER

The drive and lift inputs are closed simultane-
ously in platform mode.

Check drive/lift switch for visible damage.

Refer problem to a qualified JLG mechanic.

224

FUNCTION PROBLEM - STEER LEFT PER-
MANENTLY SELECTED

The steer left switch was closed during power-
up in platform mode.

Check if the steer left switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

225

FUNCTION PROBLEM - STEER RIGHT
PERMANENTLY SELECTED

The steer right switch was closed during
power-up in platform mode.

Check if the steer right switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

226

ACCELERATOR FAULTY - WIPER OUT OF
RANGE

There is a problem with the joystick.

Center joystick and check to see if a power cycle will clear DTC.

Refer problem to a qualified JLG mechanic.

227

STEER SWITCHES FAULTY

The steer left and steer right inputs were
closed simultaneously.

Check if the steer switches are damaged, obstructed or jammed.

Refer problem to a qualified JLG mechanic.

228

FUNCTION LOCKED OUT - ACCELERATOR
NOT CENTERED

The joystick was not centered at power-up.

Release joystick and allow to center.
Check if the joystick is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

229

FUNCTION PROBLEM - TRIGGER PER-
MANENTLY CLOSED

The trigger switch was closed during power-
up in platform mode.

Check if the trigger switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.

2210 TRIGGER CLOSED TOO LONG WHILE IN

NEUTRAL

The trigger switch was closed for more than
five seconds while the joystick was centered.

Check if the trigger switch is obstructed or jammed.

Refer problem to a qualified JLG mechanic.