5 maintenance, Hydraulic oil check procedure, Maintenance -8 – JLG R6 User Manual

Page 68: Hydraulic oil check procedure -8, Ee section 5.5), 5 maintenance hydraulic oil check procedure

Advertising
background image

SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

5-8

– JLG Lift –

3121684

5.5

MAINTENANCE

Hydraulic Oil Check Procedure

Lube Point(s) - Hydraulic Reservoir
Reservoir Capacity - See Table 5-8 on page 5-6.
Lube - Hydraulic Oil
Interval - Check Daily

NOTE: Check the hydraulic oil level with the platform in the

stowed position ONLY. Be certain the hydraulic oil has
warmed to operating temperature before checking the oil
level in the reservoir.

1. On the left side of the machine, remove the side

access door on the base frame. Locate the hydraulic
oil reservoir (1)
on the pump unit (2). Check the oil
level in the hydraulic reservoir by looking at the mark-
ings on the side. The reservoir is marked with a MAX
(maximum) marking (3)
. The oil level must be kept at
or within one (1) inch of this marking to operate prop-
erly.

2. If additional oil is required, wipe all dirt and debris

from the filler/breather cap (4) area, add proper
grade of oil. Fill until oil level is close to the MAX
marking (3),
but not over the MAX marking.

NOTE: Care should be taken not to introduce any impurities (dirt,

water, etc.) while cap is removed.

NOTE: Recommended lubricating intervals are based on

machine operations under normal conditions. For
machines used in multi-shift operations and/or exposed
to hostile environments or conditions, lubrication fre-
quencies must be increased accordingly.

Figure 5-1. Hydraulic Oil Check Procedure

Advertising