SECTION 3 - MACHINE CONTROLS, INDICATORS AND OPERATION

3121684

– JLG Lift –

3-5

Battery Charger Fault (LED Flash)

If a fault has occurred during battery charging, the (AMBER or
RED) LED on the charger LED indicator (See Figure 3-2.) will flash
corresponding to the fault which occurred. Refer to Table 3-1
following for the charger LED flash codes and their meaning.

If required, further general and troubleshooting information
about the battery charger can be found in the charger manufac-
turers Owner’s Guide.

Table 3-1. Battery Charger Fault (LED Flash)

FLASHING LED

FAULT

REMEDY

AMBER

Battery High Voltage

Upon battery voltage >2.5V per cell @ startup, charger shall flash amber LED and not
allow charging - Battery or System problem.

AMBER

Battery Low Voltage

Upon battery voltage <0.17V per cell @ startup, charger shall flash amber LED and
not allow charging - Battery or System problem.

AMBER

Failed Trickle to min V

Should battery fail to reach 1.75V per cell charge shall flash an amber LED until char-
ger is power cycled - Battery or System problem.

RED

Charger Internal Fault

Signals a hardware fault of the charger and shall indicate flashing red LED.