2 lss - load sensing system, 2 lss - load sensing system -27, 7 electric motor – JLG R6 User Manual

Page 86

Advertising
background image

SECTION 5 - GENERAL SPECIFICATIONS AND MAINTENANCE

5-26

– JLG Lift –

3121684

7742 FIELD VOLTAGE IMPROPER

The power module detected a problem in the
drive motors' power circuit wiring.

Recycle power on/off, if problem persists;

Refer problem to a qualified JLG mechanic.

7-7 Electric Motor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

8-2 LSS - Load Sensing System

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

8212 LSS PRESSURE SENSOR -

DISAGREEMENT

Pressure Sensor 1 and Pressure Sensor 2 do not
agree. The system shall assume the machine is
overloaded until the sensors agree.

Refer problem to a qualified JLG mechanic.

8213 LSS ANGLE SENSOR -

DISAGREEMENT

The angle sensor’s change in reading does not
agree with the direction of themachine
motion (lift up).

Refer problem to a qualified JLG mechanic.

8214 LSS ANGLE SENSOR -

DIRECTION DISAGREEMENT

The angle sensor’s reading when the machine
is at maximum elevation does not fall within
the high end acceptable range.

Refer problem to a qualified JLG mechanic.

8215 LSS ANGLE SENSOR -

OUT OF RANGE LOW

The angle sensor’s reading when the machine
is stowed does not fall within the low end
acceptable range.

Refer problem to a qualified JLG mechanic.

8216 LSS ANGLE SENSOR HAS NOT BEEN CAL-

IBRATED

The Angle Sensor has never been calibrated
and the control system assumes that the plat-
form is overloaded.

Refer problem to a qualified JLG mechanic.