SECTION 3 - MACHINE OPERATION

3121227

– JLG Lift –

3-5

3.5 BATTERY CHARGING

Battery Low Voltage Warning Indicators

The 10MSP Platform Control Console and Ground Control Station indicate battery low voltage at three (3) Warning Levels.

Table 3-1. Battery Low Voltage Warning Indicators.

WARNING

LEVEL

INDICATOR LOCATION

RESULT

ACTION REQUIRED

TO CLEAR FAULT

PLATFORM CONTROL LED

GROUND CONTROL LCD

LEVEL-1

• 3 LEDs/BARS Flashing with an

audible beep.

• Machine will Operate - No Con-

trol Functions Locked Out.

Charge batteries to a level of four (4)
LEDs/BARS or more before operating.

LEVEL-2

• 2 LEDs/BARS Flashing with an

audible beep.

• Platform Lift-UP Function is

Locked Out.

Charge batteries for a minimum of four
(4) continuous hours or eight (8)
LEDs/BARS lit before operating. (a)

LEVEL-3

• 1 LED/BAR Flashing with an

audible beep.

• Drive and Platform Lift-UP Func-

tions Locked Out.

Charge batteries for a minimum of four
(4) continuous hours or eight (8)
LEDs/BARS lit before operating. (a)

NOTE: (a) To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4 hours or until 8 bars

are lit on the ground station LCD Display before operating the machine. When drained to Warning Level 2 or 3, batteries must be charged until 8

bars are lit on the ground station LCD display to clear the fault code.