JLG 10MSP Operator Manual User Manual

Page 48

Advertising
background image

SECTION 3 - MACHINE OPERATION

3-20

– JLG Lift –

3121227

1. Battery Charge/Flash (Fault) Code Indicator LEDS

On normal power-up and operation this series of ten (10)
LEDs visually indicates the amount of charge remaining in
the batteries.

The number of LEDs lit will change depending on the level of
charge in the batteries.

• (+) All Three (3) GREEN LEDs lit up indicate maximum bat-

tery charge.

• Four (4) YELLOW LEDs indicate a two thirds to one third bat-

tery charge remaining.

• (–) Three (3) RED LED’s lit indicate minimum battery charge

remaining. The machine will continue to operate at this
charge level but will begin to indicate low battery voltage
warning indicators.

NOTE: For more information on Battery Warning Level Indicators

See “Battery Low Voltage Warning Indicators” on page 3-
5.

This set of ten (10) LEDs will also indicate a flash (fault) code
if other operating problems are detected by the Ground Con-
trol Station. Fault codes are also accompanied by a beeping
alert from the platform control console.

NOTE: LED Flash (Fault) Code indications that may be corrected

by the operator are shown on Table 3-2 on page 3-15 of
this manual.

2. Drive Mode Indicator

When the Drive/Lift Mode Selector Switch is set to DRIVE
MODE the round LED indicator on that portion of the display
panel will light up indicating the DRIVE Mode active. (See
page 3-21)

3. Lift Mode Indicator

When the Drive/Lift Mode Selector Switch is set to LIFT
MODE the round LED indicator on that portion of the display
panel will light up indicating the LIFT Mode active. (See
page 3-22)

4. Drive Speed Setting Indicator

The five (5) GREEN LEDs on the top of this indicator display
the drive speed setting with the TURTLE (on the left) repre-
senting the MINIMUM speed setting and the RABBIT (on the
right)
representing the MAXIMUM speed setting. (See
page 3-24)