General

NOTE: SLEEP MODE - During operation if no control functions

have been activated for 10 minutes (default programma-
ble setting), the ground control module will power the
machine down to conserve battery power. Cycle power
back on using either the main power selector switch (key)
or the emergency stop/power down button either on the
platform controller or on the ground control station.

The following conditions must be met before the machine can be
operated from the platform control console:

• Ground Control Station - Main Power Selector Switch must

be set to PLATFORM CONTROL MODE.

• Ground Control Station - Emergency Stop/Shut Down Button

must be in the RESET position (POWER ON).

NOTE: See Section 3.6 on page 3-10 for Ground Control Station.

• On Platform - If equipped with the OPTIONAL - PSL (Pro-

grammable Security Lock) it must be set to the ON position.

NOTE: See Section 3.13 on page 3-32 for PSL instructions.

• Both platform entry gates are equipped with an interlock

switch and must be completely closed before the drive and
platform lift functions can be operated.

Platform On/Off Key Switch

Set the ON/OFF Key Switch to the OFF position to power machine
down.

If necessary, when machine is not in use, remove key from plat-
form key switch to disable machine from unauthorized use.

At the Platform Control Con-
sole - Set the On/Off Key
Switch to the ON position (2)
to operate machine.

1. OFF Position
2. ON Position

1