Table 3-2. LCD Display - Operating Fault Conditions
FAULT
CODE
PLATFORM
LEDs
FLASHING
LCD SYMBOL SCREEN
LCD TEXT SCREEN
FAULT DESCRIPTION/
MACHINE CONDITION
TO CORRECT PROBLEM
—
—
Brakes Released -
(DRIVE Disabled)
To Engage Brakes - Press Brake
Release Button on Ground Control
Station
—
—
—
Charger AC Plugged In DRIVE Dis-
abled
Unplug Charger AC Power Cord
—
—
Programmable Security Lock
Password
Enter Code on PSL Keypad to
Power-Up Machine
—
3
Low Battery -
(Warning Level 1)
Charge Batteries to Four (4) Bars or
more on Indicator.
—
2
Charge Battery - (LIFT UP Dis-
abled) (Warning Level 2)
Charge Batteries a Minimum of
Four (4) Hours or eight (8) LEDs/
BARS lit.
—
1
Charge Battery - (LIFT UP/DRIVE
Disabled) (Warning Level 3)
Charge Batteries a Minimum of
Four (4) Hours or eight (8) LEDs/
BARS lit.
4
3
Tilt Condition (Platform Elevated)
DRIVE and Lift UP Disabled
Lower the Platform and Drive off
the Tilt Condition
00000.0
00000.0