Orientation, Correct incorrect, Model pirecl wired directly to ud10 – Det-Tronics UD10 FlexVu Explosion-Proof Universal Display Unit User Manual

Page 44

Advertising
background image

i-2

95-8661

4.2

UD10 DISPLAY UNIT

24 VDC –

24 VDC –

24 VDC +

24 VDC +

CALIBRATE

4-20 MA +

4-20 MA –

RS-485 A

RS-485 B

RELAY POWER (RED)

FAULT (ORANGE)

LOW ALARM (WHITE)

HIGH ALARM (YELLOW)

WIRING TO OPTIONAL

RELAY BOARD

NO USER CONNECTION

1

2

3

4

5

6

7

8

9

10

11

12

13

MODEL PIRECL

C2404

BLACK

WHITE

RED

Sensor Connector

Power Supply Connector

Output Loop

Connector

MODBUS

Connector

R

ela

y Connect

or

P1

J2

J3

J4

P2

4-20 mA +

4-20 mA –

SHIELD

COM

RS485 A

RS485 B

HIGH ALARM COM

HIGH ALARM NC

HIGH ALARM NO

AUX ALARM COM

AUX ALARM NC

AUX ALARM NO

LOW ALARM COM

LOW ALARM NC

LOW ALARM NO

FAULT COM

FAULT NC

FAULT NO

24 VDC

24 VDC

+

SHIELD

24 VDC

24 VDC

+

SHIELD

SHIELD

C

ALIBR

A

TE

24 VDC

4-20 mA

24 VDC

+

P1-3

P1-2

P1-1

J2-3

J2-2

J2-1

J4-1

J4-2

J4-3

J4-4

J4-5

J4-6

J4-7

J4-8

J4-9

J4-10

J4-11

J4-12

J3-1

J3-2

J3-3

J3-4

J3-5

P2-6

P2-5

P2-4

P2-3

P2-2

P2-1

NOTE 1

INTERNAL JUMPER REQUIRED FOR

NON-ISOLATED CURRENT OUTPUT

(SINGLE POWER SUPPLY).

NOTE 2

UD10 HOUSING MUST BE ELECTRICALLY

CONNECTED TO EARTH GROUND.

1

Model PiRECl Wired Directly to UD10

orientAtion

It is highly recommended that the pIRECl be
installed in the horizontal position.

The detector

is not position-sensitive in terms of its ability to detect

gas. However, the weather baffle assembly provides

superior performance when the PIRECL is installed

with the baffle in a horizontal position.

CORRECT

INCORRECT