Det-Tronics UD10 FlexVu Explosion-Proof Universal Display Unit User Manual

Page 5

Advertising
background image

3

95-8661

4.2

HART COmmUNICATION
A HART interface provides device status information

and field programming capability.

mAgNETIC SwITCHES
Four internal magnetic switches provide a non-intrusive

user interface that allows navigation through the menu

and adjustment of configuration parameters in the field

without the use of a HART handheld device. See Figure

1 for switch locations.

These switches are used for device configuration,

checking status and event logs, and performing

calibration. The switches are labeled as follows:

CANCEL / ESCAPE

ENTER / SELECT / MENU ACCESS

PREVIOUS or if on Main Screen:

Fault Shortcut

NExT

To actuate a magnetic switch, lightly touch the magnet

to the viewing window of the UD10 directly over the

switch icon on the faceplate.

CautIon

Handle magnets with care! Personnel wearing
pacemakers/defibrillators should not handle
magnets. Modern magnet materials are extremely
strong magnetically and somewhat weak
mechanically. Injury is possible to personnel, and
magnets themselves can easily get damaged if
allowed to snap towards each other, or if nearby
metal objects are allowed to be attracted to the
magnets.

noTe

Det-Tronics offers two magnet options for
activating internal magnetic switches. While the
two magnets can usually be used interchangeably,
the best results will be achieved if they are used
as follows: The Magnetic Tool (p/n 009700-001)
is the stronger magnet and is recommended
for activating the switches on the UD10
viewing window. The Calibration Magnet (p/n
102740-002) is recommended for applications
that involve initiating calibration or resetting the
detector by touching the side of a metal junction
box or detector housing (PIReCL, oPeCL, etc).
Throughout this manual, the term “magnet” can
refer to either device.

Access To menus
To access the menus, use the magnet to activate the

ENTER/SELECT button. This will display the Main

Menu.

The actual menu structure varies depending upon the

device that is connected to the UD10. Menus for the

various devices can be found in the corresponding

Appendix in this manual.

Some areas of the menu contain additional information,

which is indicated by the presence of an arrow on that

particular line. By placing the magnet to the glass over

the ENTER/SELECT button, the next screen with the

additional information will be shown.

The UD10 automatically returns to the main screen after

10 minutes if no activity occurs.

Quick Access/Shortcut: Fault menu
To access the fault menu quickly, when a fault is present,

touch the magnet to the glass by the PREVIOUS button.

CANCEL / ESCAPE

ENTER / SELECT

PREVIOUS

NEXT

B2426

Figure 1—Faceplate of UD10