9

Parameter data transfer

9.3

PROFIdrive parameter data channel (DP-V1)

77

Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameter response to a read error

Byte 1

Byte 2

Byte 3

Byte 4

Request reference

(mirrored)

Response identification

Axis

(mirrored)

Number of indices

0xXX

0x81

0x00

0x01

Parameter has not been read

Byte 5

Byte 6

Format

Number of values

0x44

0x01

Error

Error code without

additional information

Byte 7

Byte 8

Error code

High byte

Low byte

For the meaning, see the "

Error codes

"

( 74)