9parameter data transfer – Lenze E84AYCPM User Manual
Page 77
Advertising

9
Parameter data transfer
9.3
PROFIdrive parameter data channel (DP-V1)
77
Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter response to a read error
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
(mirrored)
Response identification
Axis
(mirrored)
Number of indices
0xXX
0x81
0x00
0x01
Parameter has not been read
Byte 5
Byte 6
Format
Number of values
0x44
0x01
Error
Error code without
additional information
Byte 7
Byte 8
Error code
High byte
Low byte
For the meaning, see the "
chapter
Advertising