2 possible causes and remedies, Memory: no access [0x01bc5531, Memory: read error [0x01bc5532 – Lenze E84AYCPM User Manual

Page 92: Memory: write error [0x01bc5533, Restart after watchdog reset [0x01bc6010, Possible causes and remedies, 0x01bc3100, 0x01bc5531, 0x01bc5532, 0x01bc5533

Advertising
background image

Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17

92

12

Error messages

12.2

Possible causes and remedies

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

12.2

Possible causes and remedies

This chapter lists all PROFIBUS error messages in the numerical order of the error numbers. Possible

causes and remedies as well as responses to the error messages are described in detail.

Connection to 8400 standard device lost [0x01bc3100]

Memory: No access [0x01bc5531]

Memory: Read error [0x01bc5532]

Memory: Write error [0x01bc5533]

Restart after watchdog reset [0x01bc6010]

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

• Network cable (plug) is defective.

• Network cable is not connected to the PROFIBUS

terminal X201.

• Voltage supply is interrupted.

Check cables and terminals.

Connect network cable to the PROFIBUS terminal X201.

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Access to memory was not possible.

Repeat the download of the application

(including module)

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Parameter could not be read.

Repeat the download of the application

(including module)

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Parameter could not be written.

Repeat the download of the application

(including module)

Response (Lenze setting printed in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Module defective.

If this occurs repeatedly, contact the Lenze service.

Advertising