11 diagnostics – Lenze E84AYCPM User Manual
Page 90

Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17
90
11
Diagnostics
11.3
Advanced diagnostic message
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Example: "Short circuit (OC1)" error in the Inverter Drive 8400
Byte
Value
[hex]
Description
1
x Standard data (PRM_Fault)
...
6
7
0A Block length of the advanced diagnostics = 10 bytes
8
81 Status message
9
00 Slot 0
10
01 Status coming
11
00
12
00
13
0B Error message 0x11C4000B "Short circuit (OC1)"
• Error type: "Warning locked"
• Subject area: 0x11C4 (current)
• Error ID: 0x000B
The error number "0x11C4000B" indicates the following:
In the "Current" subject area, an overcurrent has been detected. The error response
to this is a "Warning locked", which must be unlocked separately after the error has
been eliminated.
14
00
15
C4
16
11