4 consistent parameter data, Consistent parameter data, 9parameter data transfer – Lenze E84AYCPM User Manual

Page 80

Advertising
background image

Lenze · E84AYCPM communication module (PROFIBUS®) · Communication Manual · DMS 5.0 EN · 11/2012 · TD17

80

9

Parameter data transfer

9.4

Consistent parameter data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.4

Consistent parameter data

In the PROFIBUS communication system, data are permanently exchanged between the control

system (CPU + PROFIBUS master) and the inverter via the plugged-on slave interface module. Both

the PROFIBUS master and the CPU (central processing unit) of the control system access a joint

memory: the dual port memory (DPM).
The DPM permits a data exchange in both directions (write/read):

It could happen that a slower PROFIBUS master writing would be overtaken by a faster CPU reading

within a cycle time without any further data organisation.
In order to avoid such an impermissible state, the parameter data to be transmitted must be marked

as "consistent".

Data communication with consistent data
With consistency, either "reading" or "writing" is possible when the master and the CPU

simultaneously access the memory:

• The PROFIBUS master transfers data only as a complete data set.
• The CPU can only access completely updated data sets.
• The PROFIBUS master cannot read or write data as long as the CPU accesses consistent data.

The result becomes clear from the example below:

1. As the master can only write if the CPU does not read, the master waits until the data are read

completely by the CPU.

2. The master only writes a complete data set into DPM.

Configuring consistent data

Central processing unit

(CPU)

Dual port memory

(DPM)

PROFIBUS master

CPU wants to read!

Master wants to write simultaneously!

Central processing unit

(CPU)

Dual port memory

(DPM)

PROFIBUS master

Note!

Consistency is achieved by an appropriate PROFIBUS master configuration.
For this purpose, refer to the documentation for your configuring software.

Advertising