Technical data

General data and operating conditions

3

l

69

EDKVF9338 DE/EN/FR 4.0

3

Technical data

3.1

General data and operating conditions

General data

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

Protection of persons and equipment

Type of protection

EN 60529

IP20

NEMA 250

Protection against accidental contact according to type 1

Earth leakage current

IEC/EN 61800−5−1

> 3.5 mA

Observe stipulations and safety
instructions!

Insulation of control
circuits

IEC/EN 61800−5−1

Safe mains isolation by double (reinforced) insulation for the
terminals X1 and X5.
Basic insulation (single isolating distance) for the terminals
X3, X4, X6, X8, X9, X10 and X11.

Insulation resistance

IEC/EN 61800−5−1

< 2000 m site altitude: overvoltage category III

> 2000 m site altitude: overvoltage category II

Protective measures

Against short circuit, earth fault (earth−fault protected during
operation, limited earth−fault protection during mains
power−up), overvoltage, motor stalling, motor
overtemperature (input for PTC or thermal contact)

EMC

Noise emission

EN 61800−3

Cable−guided, up to 50 m motor cable length with RFI filter:
Category C2.

Radiation, with RFI filter and installation in control cabinet:
Category C2

Interference immunity

IEC/EN 61800−3

Category C3

Advertising