Electrical installation

Control terminals

Terminal assignment

5

l

97

EDKVF9338 DE/EN/FR 4.0

5.5.4

Terminal assignment

Terminal

Function
Bold print = Lenze setting

Level / state

Technical data

X11/K32
X11/K31

Safety relay K

SR

1st
disconnecting
path

Feedback − pulse inhibit

Open contact: Pulse inhibit is
inactive (operation)

See chapter "Technical
data"

Closed contact: Pulse inhibit is
active

X11/33

– coil of safety relay K

SR

Coil is not carrying any
current: Active pulse inhibit

X11/34

+ coil of safety relay K

SR

Coil is carrying current:
Inactive pulse inhibit
(operation)

X5/28

Controller inhibit
(DCTRL−CINH)
2nd
disconnecting
path

Controller enable/inhibit

LOW: Controller inhibited
HIGH: Controller enabled

LOW: 0 ... +3 V
HIGH: +12 ... +30 V

Input current at +24 V:
8 mA per input

Reading and processing
the input signals − 1/ms
(mean value)

X5/E1

Digital inputs
(freely
assignable)

Deactivate CW rotation / quick stop

HIGH

X5/E2

Deactivate CCW rotation / quick stop

HIGH

X5/E3

Activate fixed frequency 1 (JOG1)

HIGH

X5/E4

Set error message (TRIP SET)

LOW

X5/E5

Reset error message (TRIP RESET)

LOW−HIGH edge

X5/ST1
X5/ST2

Additional digital input (E6)

HIGH

X5/A1

Digital outputs
(freely
assignable)

Error message present

LOW

LOW: 0 ... +3 V
HIGH: +12 ... +30 V

Load capacity:
Max. 50 mA per output
(load resistance at least
480

W

at +24 V)

Update of the output
signals − 1/ms

X5/A2

Switching threshold Q

MIN

:

Actual speed < setpoint speed in C0017

LOW

X5/A3

Ready for operation (DCTRL−RDY)

HIGH

X5/A4

Maximum current reached
(DCTRL−IMAX)

HIGH

X5/39

GND2, reference potential for digital
signals

Isolated against GND1

X5/59

Connection of external voltage source
for backup operation of the drive
controller in case of mains failure

DC 24 V (+18 ... +30 V)

Current consumption:
Max. 1 A at 24 V

X6/1
X6/2

Analog input 1

Voltage input
range
Main setpoint

6

4

2

5

3

1

−10 V ... +10 V

Resolution:
5 mV (11 bits + sign)

Jumper X3

Current input
range

6

4

2

5

3

1

−20 mA ... +20 mA

Resolution: 20

m

A

(10 bits + sign)

Jumper X3

X6/3
X6/4

Analog input 2

Voltage input
range
Not active

Jumper X3 has no
effect

−10 V ... +10 V

Resolution: 5 mV
(11 bits + sign)

X6/62

Analog output 1

Monitor 1
Actual speed value

−10 V ... +10 V
max. 2 mA

Resolution: 20 mV
(9 bits + sign)

X6/63

Analog output 2

Monitor 2
Actual motor current value

−10 V ... +10 V
max. 2 mA

Resolution: 20 mV
(9 bits + sign)

X6/7

GND1, reference potential for analog